Rheem Heat Pump Service: The Alpharetta Owner’s Guide

Rheem heat pump service in Alpharetta typically runs $150 – $650 depending on the failed part, and our trucks carry the most common Rheem-compatible components so most repairs are completed same-day. If your system is blowing lukewarm air, short-cycling, or making a sound it never made before, that’s usually how you find out a specific part has given up. You’ll want a technician who can identify the exact Rheem model, match the part correctly, and put the price in writing before turning a wrench, because guessing at compatibility is how a $200 repair becomes a $2,000 one.

Call (229) 537-2086

We service Rheem heat pumps across Alpharetta, from Windward to Crabapple to the neighborhoods along Haynes Bridge Road, and Marco Benitez has walked enough of these systems to know that Rheem parts fail in predictable ways here, usually after several Georgia summers of hard running.

Which Rheem Models This Applies To

This guide covers the Rheem heat pump lines we see most in Alpharetta: the RP14, RP15, RP17, and RP20 series, plus the older RPNL and RPPC units still chugging along in homes built in the 1990s and early 2000s. Rheem uses a model number format that tells you a lot, for example, an RP1536AJ1NA is a 3-ton unit from the RP15 series. The third and fourth digits give you the capacity. If you’re reading a faded data plate on the side of the outdoor unit, that’s the number we need.

Here’s the compatibility gotcha: Rheem changed control board architecture between the RP14/RP15 generation and the RP17/RP20 units. A board that fits an RP15 will not talk to an RP17’s variable-speed compressor. The part may plug in, but the communication protocol is different, and you’ll chase faults for a week before realizing it. We match by serial number range, not by what looks similar. On the OEM versus aftermarket question: for contactors, capacitors, defrost sensors, and fan motors, quality aftermarket parts from suppliers like Mars or SUPCO hold up fine. For control boards and inverters, we use OEM Rheem parts, because the failure rate on aftermarket boards in Georgia humidity is high enough that the savings do not survive the first summer.

Explore

Styles & brands we work with

AC repair
AC repair
Furnace & heating
Furnace & heating
Heat pumps
Heat pumps
Ductless mini splits
Ductless mini splits
Carrier
Carrier
Trane
Trane
Goodman
Goodman

Signs Your Rheem Heat Pump Service Is Failing

  • Outdoor unit hums but the fan doesn’t spin. This is almost always a failed run capacitor, the small cylinder that gives the fan motor its starting jolt. In Alpharetta’s July heat, capacitors degrade fast, and this is the single most common Rheem repair we do.
  • System blows cool air in cooling mode but won’t heat in winter. The reversing valve is stuck or its solenoid has failed. On Rheem units, the reversing valve defaults to heat, so if yours is stuck in cooling, it’s likely the solenoid coil, which is a cheaper fix than a full valve replacement.
  • Unit short-cycles, on for three minutes, off for three, on again. This pattern usually points to a failing defrost control board or a low-pressure switch tripping. The board thinks the coil is icing up when it isn’t, and your compressor is paying for the confusion.
  • Ice on the outdoor coil in cooling season, thick enough to scrape. Your defrost cycle isn’t running, or the coil is starved for airflow. A blocked coil or a bad defrost sensor will do this, and continuing to run the unit against ice is how compressors die young.
  • Hissing or bubbling sound from the indoor unit, and the house never reaches set temperature. That’s refrigerant escaping through a leaking evaporator coil or a rubbed line, audible because the charge is already low. Rheem coils from the mid-2010s are known for developing pinhole leaks at the tube sheet, and this is not a job for a bottle of stop-leak.
Before & after

See the difference

Before - Recent ProjectBeforeAfter - Recent ProjectAfter
Recent Project
Before - Full RestorationBeforeAfter - Full RestorationAfter
Full Restoration
Before - Complete UpgradeBeforeAfter - Complete UpgradeAfter
Complete Upgrade

Replacement Cost & What’s Included

Most Rheem heat pump repairs in Alpharetta land between $150 and $650 installed, and the spread comes down to which part failed. Here’s what we quote across the metro:

  • Run capacitor: $150 – $250 installed
  • Contactor: $150 – $280 installed
  • Defrost sensor or thermostat: $180 – $300 installed
  • Reversing valve solenoid: $200 – $350 installed
  • Condenser fan motor: $350 – $550 installed
  • Defrost control board: $300 – $480 installed
  • Evaporator coil replacement: $450 – $650 for the labor portion, with the coil itself quoted separately by size and series

Every quote from Dalton Heating & Air Alpharetta includes the part, the labor to install it, and a written guarantee on the repair for a full year. If the part fails or the repair doesn’t hold within that window, we come back at no charge. That’s the 365-Day Done Right Promise, and it’s written on every invoice, not hidden in fine print. The price Marco Benitez writes up before work starts is the price you pay, no door-shift, no “found something else” add-on unless you approve it first in writing.

DIY or Call Us?

You can safely check a few things yourself: confirm the thermostat is set correctly, check that the breakers at the panel are fully seated, and make sure the outdoor unit isn’t buried in leaves or blocked by a fence panel. If the system is tripping a breaker, do not reset it a second time. A heat pump that trips twice has a real fault, and cycling power through a shorted compressor or a grounded fan motor will turn a repairable problem into a replacement job.

Anything involving the capacitor, contactor, control board, or refrigerant lines is not a DIY job. A capacitor holds a charge even with the power off and will knock you on your back if you grab it wrong. Refrigerant work requires an EPA 608 certification, and getting the charge wrong on an RP17’s variable-speed system will cook that compressor. This is where DIY goes from “saved $200” to “spent $4,800 on a new unit.” Call us at (229) 537-2086 and we’ll have a background-checked technician out with the right part on the truck.

FAQs

Need HVAC help in Alpharetta? Licensed & insured · within the hour response · free estimates
Call (229) 537-2086
Local Service Coverage

Request a Free Estimate in Alpharetta

Tell us what you need - Dalton Heating & Air Alpharetta responds fast. No obligation.

When you send us your details, you accept our Privacy Policy and agree that you may be contacted by call, text, or email regarding your service needs, including from the affiliated professionals who may take on the job.

Prefer to text? Send a Text
Call Now - 24/7 Dispatch